Study on heat and mass transfer of the slotted light steel-framed composite wall at minimum temperature in Harbin

Wang Zhaojun,Zhang Sumei,Cui Yongqi
2007-01-01
Abstract:The three-dimensional heat transfer performance of the slotted light steel-framed composite wall at minimum temperature is simulated using the finite element software of ANSYS. Based on the simulated results of heat transfer and the theory of moisture permeation, moisture transfer of the composite wall is calculated. The results show that there is no condensation at the inner wall surface at the minimum temperature in Harbin when the thickness of the wall is 229mm. The condensation may occur in the rock wool near the outer wall. However, there is no moisture accumulation in rock wool during heating period.
What problem does this paper attempt to address?