Investigation On Temperature Distribution Of Light Gauge Steel Frame (Lsf) Wall

Qianyi Song,Xiaobin Wu,Lin-Hai Han
2019-01-01
Abstract:Cold formed light gauge steel structures are increasing popular in construction of low rise buildings. Load bearing light gauge steel frame (LSF) wall system is the most important structural component to resist vertical loads. To resist seismic load, structural boards are usually adopted and attached on both surfaces of LSF. Oriented strand board (OSB) is one of the widely used timber structural board for LSF wall system. The structural boards can also provide support to the LSF to avoid the possible global or local buckling of the studs and increase the vertical load bearing capacity of LSF. Without suitable protection, the load bearing LSF walls with OSB board cannot satisfy a specially required fire resistance rating. In this study, a group of LSF-timber composite walls were fabricated and tested in ISO-834 standard fire for 3 hours. Different types of protection materials were considered, and thickness of the protection layers was taken as variable. Temperature distribution along the cross-section of the composite walls was measured and analysed. The data presented in this paper can be reference for evaluation and design of LSF walls in fire.