AC Flashover Performance and Discharge Process of Iced Insulator Strings

Yan WANG,Li-chun SHU,Ji-he YUAN,Xing-liang JIANG
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.09.006
2007-01-01
Abstract:The ice flashover performance is one of key issues of the outdoor insulation selection of transmission lines passing icing regions. Based on the artificial icing and electrical tests in the climate chamber, the paper studies the AC flashover performances and mechanism of XP-70 and XWP2-160 insulator strings as well as FXBW4-110/100 composite insulator under the icing condition and in the high altitude region. The experimental results show that the effect of air pressure on the flashover voltages of iced insulator strings is same as the effect on polluted insulators and the exponents of the three types of insulators, and the effects of air pressure on the flashover voltages are 0.64, 0.55 and 0.69, respectively. There is a linear relationship between the ice flashover voltage and the length of the insulator string at various air pressures. The voltage distribution of insulator string has changed after icing, which is affected by the ice states. The change is the main reason causing the decrease of electric performance of the iced insulator string. The development of partial arc on iced insulators surfaces needs more time than that on polluted insulators surfaces and is affected by the melting of the ice and shapes of the icicles. The leakage current of the iced insulator is higher than that of polluted insulator, and the leakage current is related with the string length and type of insulators.
What problem does this paper attempt to address?