New method for improving the measurement accuracy of AC/DC Kelvin bridge

Lu Huang,Zhonghua Zhang,Wei Zhao,Zhengkun Li
2007-01-01
Abstract:The ratio error caused by the unstable bridge arm resistors will occur when a traditional resistance Kelvin bridge is operated for actual measurement. Usually in DC condition it can be eliminated by changing the physical position of the measured resistor and the standard one, however in AC condition this exchange will lead to a new ratio uncertainty because of the position variation of the lead wires between the two resistors and the bridge. To solve this problem a new method named electrical exchanging is presented for the 1:1 comparison between two same nominal value resistors. All of the components of Kelvin bridge are integrated into a central plate by the connecting leads. With reasonable wiring the electrical position exchanging between the measured resistor and the standard one can be realized by exchanging the location of the four short links. At the same time a resistance Kelvin bridge operated in the frequency range from DC to 10 kHz is developed for the comparative measurement between two Tinsley 5685 AC standard resistors. The experimental results and theoretical analysis show that electrical exchanging could improve the measurement accuracy of the bridge in AC/DC conditions.
What problem does this paper attempt to address?