Porosity Test in Carbon Composites Based on a New Ultrasonic Attenuation Method

LIU Ji-zhong,ZHOU Xiao-jun,JIANG Zhi-feng
DOI: https://doi.org/10.3969/j.issn.1005-0299.2007.02.028
IF: 1.8
2007-01-01
Materials Science and Technology
Abstract:The theory and empirical equations of porosity test in carbon composites are discussed in this article.The void shape and size is correlated with the void content.The void morphology and content should be taken into account in porosity test by ultrasonic attenuation method.The ultrasonic frequency has an effect on porosity test,and the constant of the equation is correlated with the frequency.A new porosity-based ultrasonic attenuation test method is proposed.In the new method a professional data base of different kinds of material,different ultrasonic frequencies and different range of porosity content need to be established.Multi-segment fit method is used in the empirical equations accounting for the void content and shape factor.A simple example shows the porosity-based ultrasonic attenuation method can improve the porosity calculation accuracy.
What problem does this paper attempt to address?