Monte Carlo Simulations for Target Analyses

ZHANG Hui,LOU Yun,LI Pengyu,CAO Yanfeng,HOU Lina
DOI: https://doi.org/10.3321/j.issn:1000-0054.2007.z1.027
2007-01-01
Abstract:For a given energy level in an electronic linac,the X-ray distribution is then a function of many factors including the target size and material.The target size selection mainly depends on the linac energy level with tungsten chosen as the target material in most cases.The effect of the target size was analyzed with the Geant4 Monte Carlo algorithm.The results show that the target thickness significantly affects the X-ray field and that an appropriate target thickness is essential for an ideal linac output dose rate.The results also show that the effect of the target diameter can be neglected.
What problem does this paper attempt to address?