Challenges to turbine development

Shengcai Li,Shuhong Liu,Yulin Wu
2007-01-01
Abstract:After the successful installation of 14 Francis turbines in the left power house at China's Three Gorges project, damage was spotted on the guide vane of turbine. The damage occurs on the foil's lower surface in the form of horizontal strips starting from the favorable pressure gradient zone to adverse pressure gradient zone. The damage was analyzed and considered based on both metallurgical and fluid dynamics strongly suggest a new type of cavitation (erosion). In former consideration, the blue color on the heated tail of the damaged area strongly suggests similar heat treatment that creates an ideal environment for sensitization, leading to intergranular corrosion. In the latter analysis, in the case of particularly large turbines, the scale effect means that the turbulent production occurs in the area where the flow is most susceptive to cavitation inception. Numerical study shows once the initial cavitation damage spot is created, it will serve as a roughness spot for triggering cavitation inception and create another cavitation damaged area immediately downstream. This dynamic process progresses streamwise, resulting in a horizontal damage strip with a wedged head and heated tail which is dominant patterns on the guide vane.
What problem does this paper attempt to address?