Investigating the Performance of a Super High-head Francis Turbine under Variable Discharge Conditions Using Numerical and Experimental Approach

Zheming Tong,Hao Liu,Jianfeng Ma,Shuiguang Tong,Ye Zhou,Qiang Chen,Yunzhe Li
DOI: https://doi.org/10.3390/en13153868
IF: 3.2
2020-07-29
Energies
Abstract:A super high-head Francis turbine with a gross head of nearly 700 m was designed with computational fluid dynamics (CFD) simulation and laboratory tests. Reduced-scale (1:3.7) physical and numerical models of the real-scale prototype were created to investigate the hydraulic performance. According to the CFD analysis, a strong rotor–stator interaction (RSI) between guide vanes and runner blades is observed as a result of the high-speed tangential flow towards runner created by the super high water head as well as the small gaps between the radial blades. At the designed best efficiency point (BEP), there is no significant flow recirculation inside the flow passage and minor loss occurs at the trailing edge of the stay vanes and guide vanes. Maximum velocity is observed at runner inlets due to flow acceleration through the narrow passages between the guide vanes. The elbow-shaped draft tube gradually decreases the flow velocity to keep the kinetic energy loss at a minimum. The laboratory test was conducted on a reduced-scale physical model to investigate the pressure pulsations and guide vane torque (GVT) under variable-discharge configurations, which are key concerns in the design of a high head turbine. Pressure sensor networks were installed at the inlet pipe, vaneless space and draft tube, respectively. The most intense pressure variation occurs at the inlet pipe and elbow at 0.04–0.2 GVOBEP and 1.5–1.8 GVOBEP with a low frequency about 0.3 times of the runner frequency, while the vibration in vaneless zone performs stable with the blade passing frequency caused by RSI. The GVT shows a declining trend and then keeps stable as GVOs increases at synchronized condition. For the misaligned conditions, the torque of adjacent guide vanes differs a lot except at the synchronous angle and maximum absolute value at least doubles than the synchronized condition.
energy & fuels
What problem does this paper attempt to address?
The main problem this paper attempts to address is the design and evaluation of the performance of an ultra-high head Francis turbine under different flow conditions. Specifically, the study focuses on the following aspects: 1. **Design Optimization**: Optimize the design of the ultra-high head Francis turbine through Computational Fluid Dynamics (CFD) simulations and laboratory tests to achieve good hydraulic performance at a maximum head close to 700 meters. 2. **Performance Evaluation**: Evaluate the hydraulic performance of the turbine under different flow conditions, including Best Efficiency Point (BEP), Partial Load (PL), and High Load (HL) conditions. 3. **Pressure Pulsation and Guide Vane Torque**: Investigate the pressure pulsation and Guide Vane Torque (GVT) of the turbine under different flow conditions, as these parameters are crucial for the stability and lifespan of the turbine. 4. **Experimental Validation**: Validate the accuracy of the CFD simulation results through laboratory tests to ensure the reliability and effectiveness of the design. By combining numerical simulations and experimental tests, the paper comprehensively analyzes the performance characteristics of the ultra-high head Francis turbine, providing important references and guidance for the design and application of similar turbines.