On the Influencing Factors in a Pitot Tube Measurement I. Influence of Air Horn and Mounting Angle

Zhi-qiang SUN,Jie-min ZHOU,Hong-jian ZHANG,Jian HU
DOI: https://doi.org/10.3969/j.issn.1004-1699.2007.03.049
2007-01-01
Abstract:Used in working situations, extra errors are inevitably added to the measurement results of a Pilot tube due to deviations from its standard usage conditions. Aiming at investigating how the air horn and mounting angle affect a Pitot tube measurement, experiments were carried out on various Pitot tubes. The results show that, first of all, in the lower velocity measured, the diameter of an air horn had little influence on the total pressure and the measurement results had small errors compared with the reference values. Secondly, the extra errors were ±2% when the mounting angle ranged from -10° to 10°. Thirdly, the measured values of an air horn with smaller diameter were hardly affected by the flow velocity even if there existed non-zero mounting angles. These findings provide guidance for optimizing the performance of a Pitot tube.
What problem does this paper attempt to address?