Abstract:Since higher stress concentration factor (SCF) leads to lower fatigue life, it should be careful to choose the shape and dimensions of weld repair profile to avoid high SCF of welded structures in FPSOs. In this paper, two dimensional repair profiles in different geometries, such as elliptical and parabola profiles with different sizes are investigated. SCFs obtained from these repair profiles are compared with corresponding U-shaped profiles. When the half surface width is longer than the depth, the elliptical repair profiles are preferable. One of the repair profiles (E_D4R6) is applied to the connection of a lug plate and the longitudinal stiffener, to calculate the maximum principal stress after crack removal. It can he found that when the crack is removed, the original stress status can he resumed.