Comparison of the cure depth of composite resin by three kinds of curing lights

H Mo,CZ Gao
DOI: https://doi.org/10.3321/j.issn:1673-8225.2007.18.034
2007-01-01
Abstract:Aim: To discuss the cure depth of light curing composite resin Z100 cured by new curing lights [Starlight S light-emitting diode (LED) curing light, DNX-TW-518 plasma arc curing light] and traditional halogen curing light. Methods: The study was conducted in the Central Laboratory of People's Hospital, Peking University from June to December in 2006. Material: Restorative light curing composite resin Z100, mixing filling type, A2 color. Measuring instruments: DNX-TW-518 plasma arc curing light (output power 11 kW/m2, wavelength 380-540 nm), Starlight S LED curing light (output power 8 kW/m2, wavelength 440-480 nm) and Translux CL traditional halogen curing light (output power 5 kW/m2, wavelength 400-510 nm). Moulds of curing depth: 15 cylinder moulds made of polyterafluoroethylene with diameter of 4 mm and height of 8 mm, which were open in both ends for each kind. The study was conducted according to ISO 4049:2000 standards. Each mould was lured vertically, wholly and individually, with the light rob contacting with the polyester film. The lighting time of halogen curing light was 40 seconds. The lighting time of LED curing light was 10, 20 s respectively. The lighting time of plasma arc curing light was 3, 5, 10 s respectively. Only the positive side of mould was lighted. The reverse side of the mould was scraped with operating blade until the sense of hardness was the same as that of the positive side. The moulds were polished with 600# sandpaper. The thickness of remained mould was taken as curing depth (minimize to 0.02 mm). Results: 1 The average cure depth of Z100 composite resin cured by halogen curing light for 40 s was higher than that cured by LED curing light for 10 seconds [(2.285±0.149), (3.760±0.087) mm]. There were statistical significances between the two kinds of curing lights (t=19.18, P < 0.05). There was no statistical significance compared with that cured by LED curing light for 20 seconds (P > 0.05). 2 Compared with that cured by halogen curing light for 40 seconds, the average cure depth of Z100 composite resin cured by plasma arc curing light for 3, 5 seconds were lower [(1.984± 0.248), (2.575±0.129), (3.760±0.087) mm], but that for 10 seconds were higher [(4.387±0.145), (3.760±0.087) mm]. There was statistical significance compared with cured by halogen curing light for 40 seconds (t=17.20, 11.48, 6.07, P. < 0.05). Conclusion: The cure depth of light curing composite resin is different when cured by different kinds of curing lights in the same condition. Compared with the traditional halogen curing light, the two kinds of new curing lights are superior in shorter time and deeper depth of curing.
What problem does this paper attempt to address?