Experimental Investigation of Active Control of Flow Separation at Low-pressure Turbine Cascade

Jinbao Yi,Weiyang Qiao,Dawei Sun
DOI: https://doi.org/10.3321/j.issn:1000-6893.2007.05.005
2007-01-01
Abstract:The experimental investigation was performed for votex generator jets (VGJs) controlling flow separation occurred in the suction side of low pressure turbine at low Reynolds number conditions. The experiments were conducted on the low-speed linear cascade tunnel at Northwestern Polytechnical University (NPU). Cases at Reynolds numbers ranging from 19000 to 260000 were considered at the free-stream turbulence intensity about 1%, The detail measurements of skin pressure coefficient at exit and blade were applied for blowing ratio from 0 to 8, for three injection locations of 53%, 63% and 72% Cx, for four skew angles from 0° to 90°, and three Reynolds number conditions of 25000, 50000 and 100000. The results showed that the VGJs drastically reduce the suction surface boundary-layer separation at low Reynolds numbers. A minimum blowing ratio is required to reduce separation effectively. VGJs performance is essentially flat above this minimum blowing, with only a slight increase in losses at very high blowing ratios. The VGJs with skew angle of 90° are proven most effective to control the flow separation. The VGJs are proven to be the most effective when injecting around nominal separation point. At higher Reynolds numbers conditions, the VGJs become ineffective and make losses increasing.
What problem does this paper attempt to address?