Performance of varhour meters in the presence of harmonics

Xu Yixun,HaoZhong Cheng,Xiong Hugang
2006-01-01
WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS
Abstract:The importance of metering reactive power is increasing with the development of electricity market. But there are defects in reactive power metering in the presence of harmonics mainly due to mistake in phase shifting and dropped amplitude. This paper analyzes the phase-shift errors of common used varhour meters through sequence component analysis. The frequency response tests and harmonic reactive power tests are done to induction varhour meter and solid-state meter. The test data are analyzed by least square method. The analysis show that the error contribution of varhour meter's registration in the presence of harmonics are due to amplitude effects and phase effects through analysis of theory and experiments: the phase contribution will be large to both induction varhour meter and solid-state meter and may cause metering errors of double harmonic apparent power, the amplitude is decreased with increasing harmonic order and that of the induction varhour is decreased more dramatically.
What problem does this paper attempt to address?