Control-Loop Design for Three-loop Voltage Regulators With Adaptive Voltage Position Control

Xie Xiaogao,Zhang Junming,Ma Yu,Qian Zhaoming
DOI: https://doi.org/10.1109/PESC.2006.1712002
2006-01-01
Abstract:This paper proposes the control loop design for the three-loop voltage regulator (VR) to achieve adaptive voltage position control. A y-parameters model for the VR with current-mode controlled active droop method is introduced to simplify the original three-loop system to a two-loop system. Therefore the compensation network design becomes much simple. Following the theoretical analysis, simulation and experimental results demonstrate very good VR transient response.
What problem does this paper attempt to address?