Robust Tracking Dual-Loop Control of Three-Phase Voltage Source Inverters

ZHENG Xuesheng,LI Chunwen,TANG Honghai,RONG Yuanjie
DOI: https://doi.org/10.3321/j.issn:1000-0054.2008.01.038
2008-01-01
Abstract:A dual-loop controller design for three-phase voltage inverters was developed in the αβ reference frame to achieve fast transient response and good steady-state accuracy. The controller has an inner inductance current loop and an outer voltage loop, with the voltage loop design based on discrete integral sliding mode control to improve the steady-state accuracy and the robustness. When tracking a sine wave reference voltage, the settling time is 2 ms and the total harmonic distortion is 3.46% with an applied abruptly resistive load. The total harmonic distortion is 0.13% with the system parameters varying gradually. Simulations show that the controller accurately tracks the reference in the presence of load disturbances and parameter variations.
What problem does this paper attempt to address?