Cosmic ray test of a prototype of the BESⅢ drift chamber

Jian-Bei LIU,Zhong-hua QIN,Ling-Hui WU,Chang CHEN,Bao-an ZHUANG,Yuan-Bo CHEN,Yan JIN,Rong-Guang LIU,Xiao-yan MA,Yuan-yuan MA,Xiao TANG,Lan WANG,Zheng-ping XIONG,Mei-Hang XU,Gui-Fang ZHANG,Min-Xuan ZHU,Qi-Ming ZHU
DOI: https://doi.org/10.3969/j.issn.0258-0934.2005.04.004
2005-01-01
Abstract:The performance of a prototype of the BES III drift chamber filled with He/C3H8(60/40) was measured with a new designed preamplifier using cosmic rays. A good spatial resolution of 100 μm was obtained with the operating voltage of 2200 V. The result indicates that the design of the BES III drift chamber fulfills the spatial resolution requirement and the preamplifier works successfully. A beam test of the prototype is required to check the design of the BES III drift chamber in detail and with more precision.
What problem does this paper attempt to address?