Longevity studies of CSC prototypes operating with Ar+CO gas mixture and different fractions of CF
Emanuela Barberis,Nebojsa Begovic,Nicholas Haubrich,Mikhail Ignatenko,Andrey Korytov,Ota Kukral,Ekaterina Kuznetsova,Armando Lanaro,Andrew MacCabe,Predrag Milenovic,Dubravka Milovanovic,Guenakh Mitselmakher,Aleksandra Radulovic,Boris Rajcic,Jake Rosenzweig,Bingran Wang,Jian Wang,Andrew Wisecarver,Darien Wood,Emma Yeager
DOI: https://doi.org/10.1140/epjp/s13360-023-04679-7
2024-02-17
The European Physical Journal Plus
Abstract:Studies of cathode strip chamber longevity, comparing Ar+CO gas mixtures with fractions of 5%, 2%, and 0% CF , were performed using several small cathode strip prototype chambers. In each trial, a localized source of radiation was used to irradiate up to an accumulated charge of about 300 mC/cm. Additionally, longevity of a uniformly irradiated prototype operating with 2% CF was studied at the CERN Gamma Irradiation Facility GIF++. Post-hoc analysis of the chamber electrodes using spectroscopy techniques was also done.