Aging Test of a Real-Size High Rate MRPC for CBM-TOF Wall

Y. Wang,X. Fan,H. Chen,J. Wang,D. Gonzalez-Diaz,Y. Li,J. Cheng
DOI: https://doi.org/10.1088/1748-0221/7/11/p11017
2012-01-01
Journal of Instrumentation
Abstract:A new kind of low-resistivity glass has been developed. Its volume resistivity is on the order of 10(10) Omega cm and multi-gap resistive plate chambers (MRPCs), once assembled with it, can be operated at a charged particle flux in excess of 25 kHz/cm(2), with very small charge build-up at the plates. This new technology has a wide range of application in high energy physics experiments such as FAIR-CBM, LHC-ATLAS or Jlab-SOLID, to mention some. In this paper we report on results related to its long-term behavior (aging). A 6 x 2-pad CBM module has been irradiated by X-rays at a mips-equivalent flux of 15 kHz/cm(2), for 300 hours and for a released charge totaling 0.22C (50 mC/cm(2)). Tested in an electron beam before and after exposure, no degradation of the detector performances could be appreciated. As expected, compared to common glass MRPCs, the newly developed high rate counter also responds faster to sudden irradiation.
What problem does this paper attempt to address?