Aging tests of the proportional wire chambers using Ar/CF4/CH4 (74:20:6), Ar/CF4/CH4 (67:30:3), Ar/CF4/CO2 (65:30:5) mixtures for the HERA-B Muon Detector

M.Danilov,L.Laptin,I.Tichomirov,M.Titov,Yu.Zaitsev
DOI: https://doi.org/10.48550/arXiv.hep-ex/0107080
2002-04-09
Abstract:The Muon Detector of the HERA-B experiment at DESY is a gaseous detector that provides muon identification in a high-rate hadronic environment. We present our studies on the properties of several fast gases, Ar/CF4/CH4 (74:20:6), Ar/CF4/CH4 (67:30:3) and Ar/CF4/CO2 (65:30:5), which have been found to fulfill muon detection requirements. The severe radiation environment of the HERA-B experiment leads to the maximum charge deposit on a wire, within the muon detector, of 200 mC/cm per year. For operation in such an environment, the main criteria for the choice of gas turned out to be stability against aging. An overview of aging results from laboratory setups and experimental detectors for binary and ternary mixtures of Ar, CH4, CF4 and CO2 is presented and the relevance of the various aging results is discussed. Since it is not clear how to extrapolate aging results from small to large areas of irradiation, the lifetime of aluminum proportional chambers was studied under various conditions. In this paper we provide evidence that aging results depend not only upon the total collected charge. It was found that the aging rate for irradiation with $Fe^{55}$ X-rays and 100 MeV $\alpha$-particles may differ by more than two orders of magnitude.
High Energy Physics - Experiment
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to select and optimize the gas mixtures suitable for use in the HERA - B muon detector in a high - radiation environment to ensure its long - term stable operation. Specifically, the research mainly focuses on the following points: 1. **Stability in a high - radiation environment**: The muon detector in the HERA - B experiment is in an extreme radiation environment, and each wire may accumulate a charge of up to 200 mC/cm per year. Therefore, the gas mixture must have extremely high anti - aging properties. 2. **Fast response and efficient detection**: The selected gas should be able to provide a fast electron drift speed and efficient signal collection to meet the needs of muon identification, especially in a high - particle - flux environment. 3. **Chemical and physical properties**: The gas mixture needs to have good electrical properties (such as high drift speed, appropriate operating electric field), chemical stability (non - flammable, non - toxic), and a reasonable cost. 4. **Study of aging effects**: Since it is difficult to directly extrapolate the results of small - area irradiation in the laboratory to large - area irradiation situations, the research team explored the aging rates and their dependencies of different gas mixtures through experiments under various conditions (such as Fe - 55 X - ray and 100 MeV α - particle irradiation). ### Specific problems of the research - **Gas selection criteria**: Determine the gas mixtures suitable for the HERA - B muon detector, especially the performance of Ar/CF₄/CH₄ (74:20:6), Ar/CF₄/CH₄ (67:30:3) and Ar/CF₄/CO₂ (65:30:5) mixtures. - **Aging mechanisms**: Study the aging mechanisms of these gas mixtures in a long - term high - radiation environment, including phenomena such as polymer deposition and electrode corrosion, and evaluate their impact on the detector performance. - **Optimization of operating conditions**: Optimize the proportion of the gas mixture and operating conditions (such as electric field strength) through experimental data to achieve the best detection efficiency and stability. ### Formula representation The aging rate \( R \) is usually parameterized as the normalized gas gain loss: \[ R = -\frac{1}{G} \frac{dG}{dQ} \quad (\text{% per C/cm}) \] where \( G \) is the initial gas gain and \( dG \) is the gain loss after the accumulated charge \( Q \) on the unit - length wire. In summary, this paper aims to find the best gas mixtures suitable for the long - term stable operation of the HERA - B muon detector in a high - radiation environment through systematic research and experiments, and to deeply understand the aging mechanisms of these gases.