DETECTORS AND EXPERIMENTAL METHODS Studies of dE/dx measurements with the BESIII

Cao Xue-Xiang,Li Wei-Dong,Roy A. Briere,Liu Chun-Le,Mao Ze-Pu,Chen Shen-Jian,Deng Zi-Yan,He Kang-Lin,Huang Xing-Tao,Huang Bin,Huang Yan-Ping,Jia Lu-Kui,Ji Xiao-Bin,Li Xiu-Rong,Liu Chun-Yan,Liu Huai-Min,Ma Qiu-Mei,Ma Xiang,Qiu Jin-Fa,Wang Da-Yong,Wu Ling-Hui,Wu Zhi,Yuan Ye,Zhang Xue-Yao,Zhao Chuan,Zhang Yao,Zou Jia-Heng
DOI: https://doi.org/10.1088/1674-1137/34/12/012
IF: 2.944
2010-01-01
Chinese Physics C
Abstract:The Beijing Spectrometer HI (BESIII) is a general-purpose detector used for the study of tau-charm physics at the Beijing Electron-Positron Collider II (BEPC II). This paper presents our studies of the dE/dx measurement in the drift chamber of BESIII, which is important for the identification of charged particles. Corrections applied to the dE/dx measurement in data reconstruction are discussed. After our current dE/clx calibration, a resolution of about 6% has been obtained for minimum ionization particles, and a 3 sigma K/pi separation is obtained for momenta up to 760 MeV/c. These results meet the design goals of the BESIII drift chamber.