A glucose oxidase sensor based on screen-printed carbon electrodes modified by polypyrrole.

Hui Xu,Guang Li,Jieying Wu,You Wang,Jun Liu
DOI: https://doi.org/10.1109/IEMBS.2005.1616826
2005-01-01
Abstract:A disposable amperometric biosensor for detecting blood glucose has been developed. The sensor is based on a screen-printed electrode prepared by electrochemical polymerization of pyrrole with glucose oxidase (GOD) and LiClO<sub>4</sub> dopants. In citric acid buffer (pH5.0), GOD with negative charges is immobilized within electropositive polypyrrole matrices onto a carbon electrode surface. Afterward, the electron transfer mediator, potassium ferricyanide is immobilized by adsorption. Experimentally the compositions of pyrrole, LiClO<sub>4</sub> and potassium ferricyanide are optimized. Amperometry is used for the determination of glucose concentration. Four microliters of glucose solution is needed for one test, and the response time of the sensor is 70s. The amperometric response of the enzyme electrode is linear in the range of 1-30 mM.