Experiment investigation on transient heat transfer in rotor-stator system with high-positioned air inflow

罗翔,徐国强,丁水汀,陶智
DOI: https://doi.org/10.3969/j.issn.1001-5965.2004.06.006
2004-01-01
Abstract:A gas turbine disk was simplified to be a shrouded rotor-stator system with high-positioned air inflow and the rotor was heated at rim. The rotor diameter is 400 mm and its maximal rotating speed is up to 3000 r/min. Transient heat transfer characteristics of the rotor were investigated experimentally as the rotational Reynolds number and the mass flow rate were changed. The results show that the mass flow rate could always have significant effects on average Nusselt number of the rotor. The rates of temperature vs time in everyplace are almost the same. The rotational Reynolds number has a few effects on averaged Nusselt number in this experimental range. The rate of temperature vs time at high radius is larger than that at low radius under different changes of rotational Reynolds number.
What problem does this paper attempt to address?