Experimental study of a traveling-wave thermoacoustic prime mover

金滔,BRETAGNE Emmanuel,陈国邦,FRANCOIS Maurice-Xavier
DOI: https://doi.org/10.3321/j.issn:0371-0025.2003.04.015
2003-01-01
Abstract:Thermoacoustic prime mover can convert thermal energy into acoustic energy through thermoacoustic effect. It attracts more attention due to the advantages of its lack of moving component, simplicity and stability. Compared with standing-wave thermoacoustic prime mover, the traveling-wave thermoacoustic engine, which is the topic of present experimental study, is considered to be capable of achieving much higher efficiency. The emphasis is made on design and fabrication of an experimental setup of the thermoacoustic-Stirring prime mover. The pressure oscillations of 66 Hz and 23 Hz were obtained, with helium and nitrogen as working fluid respectively. The influences of heating power and heating temperature on pressure amplitude were investigated and the contrast test for before and after installation of jet pump was carried out.
What problem does this paper attempt to address?