Performance Comparison of Thermoacoustic Engine with Gas-Liquid and Gas Oscillation

TANG Ke,LEI Tian,LIN Xiao-gang,JIN Tao
DOI: https://doi.org/10.3785/j.issn.1008-973x.2011.07.017
2011-01-01
Abstract:A standing-wave thermoacoustic engine with a U-shaped resonant tube was constructed in order to reduce the resonant frequency and increase the pressure ratio.A liquid column was introduced into the U-shaped resonant tube,forming the gas-liquid coupling oscillation with the gas working fluid in the thermoacoustic core.Experiments for performance comparison of the thermoacoustic engine with gas-liquid and mere gas oscillation were constructed with water as the liquid column and with nitrogen and helium as the working gas,respectively.Experimental results indicated that both nitrogen-water and helium-water coupling oscillation systems realized a resonant frequency below 8 Hz,which was obviously lower than that of either nitrogen or helium gas oscillation system.A larger pressure ratio was observed in the gas-liquid coupling oscillation thermoacoustic engine,compared with mere gas system.Relatively lower resonant frequency and larger pressure ratio are advantageous for the performance improvement of thermoacoustically driven pulse tube refrigeration at cryogenic temperature.
What problem does this paper attempt to address?