The application of statistical parameters of phase resolved PD distribution to aging extent assessment of large generator insulation

Hengkun Xie,Bo Yue,Xiang Sun,Jiancheng Song
DOI: https://doi.org/10.3969/j.issn.1671-8267.2003.01.001
2003-01-01
Abstract:Objective: To investigate the characteristic parameters employed to describe the aging extent of stator insulation of large generator and study the aging laws. Methods: Multi-stress aging tests of model generator stator bar specimens were performed and PD measurements were conducted using digital PD detector with frequency range from 40 kHz to 400 kHz at different aging stage. Results: From the test results of model specimens it was found that the skewness of phase resolved PD distribution might be taken as the characterization parameters for aging extent assessment of generator insulation. Furthermore, the measurement results of actual generator stator bars showed that the method based on statistical parameters of PD distributions are prospective for aging extent assessment and residual lifetime estimation of large generator insulation. Conclusion: Statistical parameters of phase resolved PD distribution was proposed for aging extent assessment of large generator insulation.