Verification Test of Second Shutdown System of HTR-10

周惠忠,黄志勇,刁兴中,杨念祖,曹丽
DOI: https://doi.org/10.3969/j.issn.0258-0926.2002.01.012
2002-01-01
Abstract:The neutron absorption spheres system is the second shutdown system of the 10 MW High-Temperature Gas-Cooled Test Reactor (HTR-10). This system is designed for emergent shutdown by spheres falling down into core reflector when the control rod system is out of operation. Before the re-start of the nuclear reactor, the spheres are transported from the core reflector back to spheres storage tanks beneath the reactor pressure shell top lid by pneumatic conveying process. Seven sets of absorption sphere shutdown system equipment are verified by thermal test and pneumatic conveying test in laboratory and on the HTR-10. System parameters including spheres falling down time, conveying time, spheres level indicator, Rose Motor gas flowrate, and valves open-close state are acceptable.
What problem does this paper attempt to address?