Experimental Study for Radiative Heat Transfer of High Moisture Flue Gas

张坤竹,张衍国,吴占松
DOI: https://doi.org/10.3321/j.issn:1000-0054.2002.12.028
2002-01-01
Abstract:Municipal solid waste is an unusual energy source with a much higher moisture than normal fuels. The radiative heat transfer characteristics of high moisture content gas from municipal solid waste boilers was studied experimentally according to heat balance theory. The experiments used three different diameter tubes (105 mm, 150 mm and 208 mm), different gas temperatures from 300 ℃ to 800 ℃, and different moisture tractions from 20% to 50%. The results showed that the radiative heat transfer from the highmoisture flue gas was much higher than for dry gas, so previous formulas can not be applied to high moisture gas. A new expression has been developed for high moisture content fuel gas from the experimental data for the design municipal solid waste boilers.
What problem does this paper attempt to address?