On the Furnace Design of Calculation of Circulating Fluidized Bed Boiler Fired Municipal Solid Waste

LIU Qing,YU Hai-yang,ZHANG Shou-yu,XING Xing,JIANG Wen-bin,WANG Wei
DOI: https://doi.org/10.3969/j.issn.1672-4763.2007.06.005
2007-01-01
Abstract:The furnace is the key component of municipal solid waste(MSW) fired circulating fluidized bed boiler.The combustion process and characteristic of MSW under CFB is discussed,and the heat transfer in combustor of CFB is researched.The MSW were collected from some typical cities in China and measured,of which results suggest that the low heating value of MSW should be 5 400~6 200 kJ/kg in design.In order to decrease the emission form MSW fired CFB boiler,the temperature in main loop must be kept in uniform and high lever,which can be control by the ratio of coal in the fuel.The excess air coefficient at the exit of furnace could be 1.2 instead of 1.4 to 1.6.The radial fraction in heat transfer in CFB is quite lower compared with pulverized coal boiler,and the contribution of particle redial is prominent than that of ternary atom gas.Thus the effect of gas component caused by moisture in MSW on radial heat transfer could be ignored under CFB condition if the fluidized velocity and solid suspension density is same.However,in case the moisture in MSW increase,the total gas volume will increase and the fluidized velocity as well as the solid suspension density will increase,which will lead to the heat transfer increasing.