Experimental Study on Municipal Solid Waste Incineration with 1MW CFBI

LI Qing-hai,ZHANG Yan-guo,REN Gang-lian
DOI: https://doi.org/10.3969/j.issn.1672-4763.2005.05.015
2005-01-01
Abstract:The municipal solid waste incineration experiment had been taken in a pilot of 1MW Circulating Fluidized Bed Incinerator(CFBI).In this experiment,temperature distribution and flue gas concentration of CO,NO_(x) and SO_2 along with the height of furnace had been measured.The result shows that the temperature distribution of furnace is different between waste incineration and coal combustion,and the waste incinerator needs larger dimension of height in furnace.The result also indicates that NO_(x) in CFBI is low enough to satisfy the national standard of environment protection without any treatment.This paper may be provided the reference in the design and operation of CFBI.