COMPARATIVE STUDY ON TWO RADIATIVE TEMPERATURE IMAGE MONITORING METHODS AND ASSESSMENTS FOR THEIR APPLICABILITY

周怀春,韩曙东,郑楚光
DOI: https://doi.org/10.3321/j.issn:0258-8013.2002.06.024
2002-01-01
Abstract:Bichromatic and monochromatic radiative temperature image monitoring methods have been studied and compared. Calculation results show that, if the gray radiative property is assumed for the medium inside a furnace, the radiative energy received from the boundary of the furnace does not obey the radiative laws such as the Wien's law. This is caused by the reflection of the radiative energy from the wall surface, which makes the temperature profiles/images measured according to the Wien's law could not be accepted. Even so, if the measuring direction of the reference temperature using a bichromatic pyrometer points closely to the highest temperature zone, the temperature profiles/images measured from the monochromatic method are still reasonable. Since the storage elements allotted to every one of the red, green and blue colors are limited, and the range of the flame temperatures is wide, the differences between the single colors are very large, and the simplified bichromatic method has a limited applicability. Finally, a new method is proposed, which takes the advantages of the bichromatic and monochromatic methods and avoids their disadvantages.