Measurement Performance of an Optical CCD-based Pyrometer System

Tairan Fu,Zangjian Yang,Luping Wang,Xiaofang Cheng,Maohua Zhong,Congling Shi
DOI: https://doi.org/10.1016/j.optlastec.2009.10.008
IF: 4.939
2009-01-01
Optics & Laser Technology
Abstract:The measurement performance of a CCD-based pyrometer system using a three-color method was evaluated for scientific and engineering metrology. The relationships between the system parameters (exposure time and sensor gain) and the intensity measurements in an integrating sphere experiment were determined for a specific CCD sensor. The pyrometer system uses the three-color method based on the intensity ratio without geometry calibrations. The field measurement characteristics and the effectiveness of coupling the three-color channels were investigated in terms of the temperature measurement uniformity, temperature sensitivity and temperature range of the pyrometer system in standard blackbody tests. The results showed that the temperature non-uniformity is not proportional to the intensity non-uniformity and is in the range of 0.13–2.14%. The relative temperature sensitivities of intensity ratios for different channel combinations are different, which may provide a way to improve the measurement results. The temperature range bandwidth for object with a non-uniform temperature distribution varies from 190 to 270K for this specific CCD-based pyrometer. The performance evaluation conclusions for the system with this specific CCD sensor are general and applicable for pyrometer systems using other CCD sensors.
What problem does this paper attempt to address?