Abstract:Three-color pyrometry with the non-calibration mode was used as an extension of two-color pyrometry.Based on the inherent measurement uncertainties,the analyses of pyrometry optimization were carried out.The optimization purpose was to investigate the effects of inverse algorithms and wavelengths combinations on temperature measurements.Through numerical simulations based on the measurement uncertainties,different iterative algorithms for three-color method and traditional two-color method were compared to determine the optimum iterative algorithm.The choice of wavelengths combination is another important optimization issue.Due to the coupling characteristics of data processing of three wavelength channels,the effects of spectrum wavelengths to measurements greatly differed from the disposals of single-color method and two-color method.Through numerical analyses,the optimization combinations of three wavelengths under the specified measurement conditions were also obtained.The above discussions are necessary for the actual measurement applications of pyrometry.
What problem does this paper attempt to address?