Safety Analysis of Spent Fuel Element Storage in 10 MW High Temperature Gas-Cooled Reactor

肖宏伶,刘继国
DOI: https://doi.org/10.3321/j.issn:1000-0054.2001.10.015
2001-01-01
Abstract:Approximately 90000 spent fuel elements will be discharged from a 10MW high temperature gascooled reactor (HTR10) in its lifetime. The activity of the radioactive fission products in these spent fuel elements will reach 1.0×10 16 Bq, so these spent fuel elements should be properly managed. HTR10 spent fuel elements will be discharged into leadsteel containers, with each container designed to receive 2000 fuel elements. These containers will be stored in a concrete compartment inside the reactor building and cooled by air. This paper analyzes the release of the radioactive nuclides, the critical safety parameters and the irradiation shielding. The results show that the safety requirements can be met in the HTR10 spent fuel element storage compartment.
What problem does this paper attempt to address?