Experiment and Analysis of Fission Product Activity in Primary-Loop of 10 MW High-Temperature Gas-Cooled Reactor

Cao Jianzhu
Abstract:Based on the precise measurements of the activity and component of fission products in the primary helium of 10 MW High-Temperature Gas-Cooled Reactor (HTR-10),the feature of the fission product released from the fuel element was analyzed,meanwhile,the failure fraction of the fuel particle or the U-contamination was directly deduced,and the radiation safety of HTR-10 was proved.The activity of inert gas nuclides in sample was experimentally measured,and the primary radioactivity was deduced.In the experiment ~(85m)Kr,~(87)Kr,~(88)Kr,~(133)Xe,~(135)Xe,~(135m)Ke,~(138)Xe,~(88)Rb,~(138)Cs were detected and measured.Through the comparison between the experimental results and the calculated ones,the U-contamination of graphite ball was obtained to be less than 5.7×10~(-7).
Chemistry,Physics,Engineering
What problem does this paper attempt to address?