Radiation sources and shielding design of process system for 10 MW high temperature gas-cooled test reactor

Jianzhu Cao,Yuanzhong Liu,Ling Yang
2000-01-01
Abstract:The radiation sources in various equipment of process systems related to helium coolant for 10 MW high temperature gas-cooled test reactor (HTR-10) were introduced. Calculations have been performed for the radiation shielding of various equipment rooms using the program QAD-CG. The results indicate that the radiant source intensities in these equipment are so low that the radiation dose rates outside the most equipment are very small even without additional shield for them. This facilitates repair and maintenance of these equipment. Moreover, the requirements for integrated shielding of the rooms where the equipment is located are not strict, which can be met with 10 or 20 cm-thick concrete wall that is demanded by the structure design of building.
What problem does this paper attempt to address?