Calculation of Temperature Field of Biological Shield in HTR

盛选禹,王联奎
DOI: https://doi.org/10.3321/j.issn:1000-7857.2008.13.005
2008-01-01
Abstract:High Temperature Gas-cooled Reactor (HTR) is one of the new generation reactors with inherent safety features. Its biological shield, a part of confinement, is made of reinforced concrete. Because concrete material can not endure high temperature, it should be cooled by another system. The Abaqus 6.7 finite element commercial software was used to calculate the temperature distributions in biological shield under normal condition and in component cooling water system under shut-down condition. The results show that the maximum temperature is lower than the temperature limitation under normal condition, while under component cooling water system shut-down condition, the maximum temperature is lower than 100℃ after 7 days. In other words, the shield cooling system can provide enough cooling for the biological shield.