Calculation on Temperature Field of Steam Generator Cavity Concrete Wall in HTR

LIU Sheng,SHENG Xuan-yu,KANG Fang-liang
2010-01-01
Abstract:The finite element software ABAQUS 6.7 was used to calculate the field temperature of steam generator cavity concrete wall under normal condition and Component Cooling Water system shut-down con-dition.The calculation result shows that the maximum temperature is lower than that of the temperature limi-maximum temperature is lower than 100℃ after 7 days.The cooling system can provide enough cooling for the concrete wall.