Time-Frequency Analysis on Pulse Current of Partial Discharge by Adaptive Spectrogram

王国利,郝艳捧,李彦明
DOI: https://doi.org/10.3321/j.issn:0253-987X.2001.08.005
2001-01-01
Abstract:Pulse current of partial discharge (PD) is a non-stationary signal, which has multi-component harmonic terms and time-varying spectrum. Using adaptive spectrogram (AS), the pulse current of PD was analyzed. For comparison, three joint time-frequency analysis (JTFA) methods were used. They are short-time Fourier transformation (STFT) based spectrogram, Wigner distribution (WD) and Choi-Williams distribution (CWD). The results show that AS has high resolution on both frequency-domain and time-domain without the cross-term defects and that it can describe how the spectral content varies with time. So AS can be set as the reference of PD pattern recognition. The time-frequency spectrum shows that the frequency spectrum of a PD signal contains harmonics up to 1 GHz, in some cases even higher than 1 GHz, which provides a reference for ultra-high-frequency (UHF) and ultra-wide-band (UWB) detection.
What problem does this paper attempt to address?