Influence of Throat Area of Furnace Chamber on the Aerodynamics for W-Shape Flame Boiler

Liming He,Gang Che,Tongmo Xu,Shien Hui,Houzhang Tan,Xiao Yan,Weijiang Xu
DOI: https://doi.org/10.3321/j.issn:0253-987X.2000.07.004
2000-01-01
Abstract:Cool state modeled experimental investigation has been made in a model of the 360 MW W-shape flame boiler imported by Luohuang Power Station from Stein corporation in France. The flow field in the boiler was measured by a hot-wire anemometer. Flow field patterns were obtained for different relative throat areas of furnace chamber. Analyses and comparison of velocity distribution were made in addition to examining the fullness of air flow and the flow rate of average efficient momentum in the boiler. It is beneficial to firing and burning out of pulverized coal injected into furnace chamber with reduced throat area. This can decrease the lash of high temperature gas against throat, front and rear arches of furnace chamber as well as cool ash bucket. Attainment of lower furnace clinker in these positions is thus made possible. High temperature gas washing out front and rear walls of furnace can also be dropped such that high temperature corrosion of water cooling walls can be reduced.
What problem does this paper attempt to address?