Influence of Secondary Air Angle on Flow Field in Down-Fired Furnace Determined by Cold-Flow Modeling Experiment

杨文闯,杨卫娟,周志军,袁炜东,陈瑶姬,周俊虎,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973x.2013.01.020
2013-01-01
Abstract:Focusing on the problems of high NOx emissions in down fired boilers,a new combustion technology was presented for down fired boilers,hot air packing low-NOx combustion technology(HAP),and its cold-flow modeling experiments were conducted.HAP technology adds the secondary hot-air ports in the furnace hopper and bottom on the basis of the prior down fired boiler.The cold-flow modeling experiments prove that HAP technology has a much better airflow distribution compared with the prior W flame technology in the lower furnace.HAP technology produces a deeper penetration depth of the primary air and a higher filling fullness of air flow in the lower furnace.The adherent air flow towards the furnace wall does not appear obviously,which implies little risk of slagging.Different injection angles of the front and rear walls' secondary hot-air and the hopper secondary hot-air were researched.The wall secondary air with the injection angles of 45° makes a deeper penetration depth,higher filling fullness of air flow and good adherent air flow.Penetration depth of the primary air decreased and adherent air flow became worse when increasing the angles of the hopper hot-air.The filling fullness of air flow increases firstly and reduces afterward with the increasing angles of the hopper hot-air,and reaches a maximum when the angle is 66°.