Hydrodynamics in an Airlift Inner-Loop Three-Phase Biological Fluidized Bed
Y. Qu,T. -F. Qin,B. -X. Shen,J. -C. Liu
DOI: https://doi.org/10.1080/15567036.2010.527908
2015-01-01
Abstract:In order to meet the demand of developing a wastewater treatment, the hydrodynamics, such as gas holdup, cycle time, uniform mixing time, and volumetric mass transfer coefficient of oxygen, were studied in this article. When gas velocity is 200 L/h and solid holdup is 6%, the gas holdup is 21.8%. When gas velocity is 180 L/h and solid holdup is 5%, the liquid cycle time is 8 sec. When gas velocity is 240 L/h and solid holdup is 3%, the liquid uniform mixing time is 31 sec. When gas velocity is 200 L/h and solid holdup is 5%, the volumetric mass transfer coefficient of oxygen KLa is 23.37 min−1. Meanwhile, oily wastewater was studied to verify the reliability of hydrodynamics’ performance in the reactor, where chemical oxygen demand and total petroleum hydrocarbon removal are up to 96.39 and 96.43%, respectively, when gas velocity is 180 L/h and the solid holdup is 3–5%.