High temperature performance test of hot gas duct of 10 MW high temperature gas-cooled reactor

Zhiyong Huang,Meisheng Yao,Bing Han,Yuanhui Xu,Jun Li,Xuedong He
1998-01-01
Abstract:A horizontal coaxial double tube hot gas duct is used for 10 MW high temperature gas-cooled reactor. The duct links the core and steam generator. A counterflow of cold and hot helium gas was formed outside and inside the duct model. Its thermal performance test was conducted on a test loop using helium as medium. The duct was undergone 20 times pressure cycle test in the pressure range from 0.1 MPa to 3.4 MPa and 18 times temperature cycle in the temperature range from 100 °C to 950 °C. The results show that the duct can resist heat flux, pressure variation and temperature variation.
What problem does this paper attempt to address?