Numerical Analysis of the Hot Spot of the Heat Transfer Tube Wall in an HTGR Helical Tube Once Through Steam Generator

马越,李晓伟,吴莘馨
2013-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:High Temperature Gas-cooled Reactor (HTGR) demonstration power plant uses a helical tube once through steam generator. Due to the effects caused by helium cross flow over tube bundles and secondary flow in helical tubes, the wall temperature in the circumferential direction is uneven. Investigate the helical tube wall temperature distribution by numerical method has important meanings for the design of the steam generator. The local heat transfer coefficients in the helical tube are numerically simulated with its working conditions. Then the local heat transfer coefficients are set as the convective boundary condition to calculate the wall temperature distribution with helium cross flow over the tube. The results show that the highest temperature of the tube wall is located between the top and the side of the helical axis. The hot spot caused by the heat transfer non-uniformity is about 15°C.
What problem does this paper attempt to address?