Experimental Study of Steam Generator Stability of 10MW High Temperature Reactor

Huaiming Ju,Zhiyong Liu,Zhiyong Huang,Jun Li,Xuedong He
DOI: https://doi.org/10.3969/j.issn.0258-0926.2000.06.004
2000-01-01
Abstract:The two-tube engineering scaling experimental loop for helical-tube once-through steam generator of 10 MW high temperature gas cooled reactor was introduced, and its technical features and parameters were presented. The loop uses high-temperature helium as the thermal source and is in full scale to simulate the 30% generator load for two-phase flow stability verification test under various conditions: inlet sub-cooling degree, outlet steam pressure, flow rate and inlet resistance. The results and analysis indicate that under 30% generator load by design, steam outlet pressure range (2.5-4.0 MPa), feed water temperature range (75-180°C) and inlet throttle resistance larger than 40 kPa, the loop operates in stable status. The steam generator is unable to be operated in stable states when load is less than 20%.
What problem does this paper attempt to address?