1997-01-01
Abstract:The way of thermal cycle for low temperature nuclear heating reactor was analysed in detail, and some power cycles were enumerated, such as aqueous vapor Rankine cycle, aqueous vapor volume expansion cycle. The characteristics of heating and cooling source in 5 MW, 200 MW, 500 MW nuclear heating reactor for thermal-power co-supply had been calculated, analyzed and compared for various ways of cycles. The result is that the heating sources which are offered by nuclear heating reactors with different parameters require different power cycles in order to be adapted for them. It is proposed that when the temperature difference between the core and the outlet is relatively small, the aqueous vapor Rankine cycle is preferably selected, however, when the temperature difference is large, the aqueous vapor volume expansion cycle is preferred.