Studies on the Chemical Kinetics in Flow Injection Analysis System

Z Liu,GW Zou,YK Zhang
1997-01-01
Abstract:Covection-diffusion model was used to study the chemical kinetics in flow injection analysis(FIA) system, Based on the expression of concentration distribution of physical dispersion of sample without chemical reaction, the expressions of concentration distribution of product in single-line FIA system with first-order and second-order chemical reaction under certain conditions were derived by mathematical inductive method, The analytical solutions are very simple so that they can be applied to simulate the produced curves with computer easily, The experimental fact that double-humped peak occurred when sample volume is very large in second-order reaction system was interpreted by the results computer-simulated. In addition, other information concerning chemical kinetics was discussed.