Enhanced Refractive Index Sensor Using a Combination of a Long Period Fiber Grating and a Small Core Singlemode Fiber Structure

Qiang Wu,Hai Ping Chan,Jinhui Yuan,Youqiao Ma,Minwei Yang,Yuliya Semenova,Binbin Yan,Pengfei Wang,Chongxiu Yu,Gerald Farrell
DOI: https://doi.org/10.1088/0957-0233/24/9/094002
IF: 2.398
2013-01-01
Measurement Science and Technology
Abstract:An enhanced refractive index (RI) sensor based on a combination of a long period fiber grating (LPG) and a small core singlemode fiber (SCSMF) structure is proposed and developed. Since the LPG and SCSMF transmission spectra experience a blue and a red shift respectively as the surrounding RI (SRI) increases, the sensitivity is improved by measuring the separation between the resonant wavelengths of the LPG and SCSMF structures. Experimental results show that the sensor has a sensitivity of 1028 nm/SRI unit in the SRI range from 1.422 to 1.429, which is higher than individual sensitivities of either structure alone used in the experiment. Experimental results agree well with simulation results.
What problem does this paper attempt to address?