Pollutant removal of a new spray drying/incineration demanstration project with capacity of 600 t/d for sludge treatment

Cuiping Wang,Qilin Yu,Zhiyong Gao,Shouxiang Sheng,Changmin Wu,Kaijun Wang
2013-01-01
Abstract:The new spray drying/incineration process is an integrated technique which was designed based on our country's national conditions to utilize the high temperature flue gas to dry the dewatered sludge. The pollutants removal and performance of this new process has become a focus. Therefore, we determined the running performance and pollutant removal of the new sludge spray drying/incineration demonstration project with capacity of 600 t/d for sludge treatment. The results show that the temperatures of flue gas and dried sludge particles remain stable at (96±10)°C and (72±8)°C, respectively, under the automation control. There is no dust explosion risk in the spray drying tower and TVOC concentration is below 0.025 mg/m3. The direct contact between high temperature flue gases with spayed wet sludge makes the drying process rapid and thermal reuse efficiency as high as 80%. The indicators of the discharged flue gas can meet the Solid Waste Incineration Pollution Control Standard (GB18485-2001).
What problem does this paper attempt to address?