Single Phase to Ground Fault Section Location Based on Characteristics of Traveling Wave Refraction and Reflection
YAN-GANG SHI,ZI-JIA HUI,ZE-YU GU,YONG-ZENG LI
DOI: https://doi.org/10.12783/dteees/epee2017/18107
2018-01-01
DEStech Transactions on Environment, Energy and Earth Sciences
Abstract:For single phase to ground fault in distribution networks, fault locating using traveling wave measured at one terminal only need to detect the arrival time of the initial wave head of the line mode and the zero mode. But the zero mode wave velocity is unstable. This paper proposes a fault section location method using only line mode traveling wave. It analyzes wave refraction and reflection performance at the fault point, the branch point and the end of the line. The path differences between reflected waves and the initial incident wave are estimated through Hilbert Huang Transform by indexing the arrival time of the initial wave and reflected waves, if the line mode wave velocity is assumed. Combined with the topology of distribution network, the possible propagation paths can be obtained to identify the fault section. The effectiveness of the proposed method is verified by experiments in the actual distribution network. Introduction In the distribution networks, the probability of occurrence of single phase to ground fault accounts for more than 80% of all types of faults. When single phase grounding occurs, it is of great significance to find fault location timely to improve power supply reliability. Fault location method based on transient traveling wave signal has been widely concerned because it is not affected by fault types, transition resistance and neutral grounding mode[1-2]. Modern traveling wave positioning methods are generally divided into single-ended method and double-ended method. The double-ended method uses the difference of arrival time of line mode traveling wave head between the two end measurement points to achieve fault location, requiring accurate global positioning system (GPS) on the time device [3]. Since the reflected wave from the fault point is difficult to identify, the single-ended method based on the initial traveling wave and the fault point reflected wave is difficult to apply in the actual distribution network [4,5]. Another single-end positioning method is based on the velocity difference between line mode and zero mode wave. But the zero mode wave velocity is unstable with the fault distance and the traveling wave frequency, and the error is large [6-8]. The line mode traveling wave is easy to obtain and its velocity is stable [7], from which the time of the initial wave and each reflected waves arriving at the same measuring point can be obtained, as well as the time difference between reflected waves and the initial wave. And combined with the line mode traveling wave velocity, the distance differences are obtained. As distribution network topology is known, the possible traveling paths of traveling waves are determined, and then the fault section is located. Propagation Characteristics of Fault Traveling Wave According to the superposition principle, the single phase to ground fault of the distribution line is equivalent to the fault instantaneously add a pulse signal source at the fault point, and the fault traveling wave propagates along the line to both sides of the fault point. According to the wave