Flight Test System for Measuring the Aerodynamic Parameters of Rotor Blades

黄有为,程卫真,李岩,李万新
DOI: https://doi.org/10.13741/j.cnki.11-1879/o4.2012.04.006
2012-01-01
Optical Technique
Abstract:A novel flight test system is developed for measuring the blade aerodynamic parameters of a certain helicopter.The aerodynamic parameters of several blades are measured simultaneously.The motion parameters of the blades,including the flap,lag and pitch angles,are measured by two-dimensional position sensitive detectors responding to the changes in position of the luminous points mounted on the blade surface.The strains on the blades are measured by Fiber Bragg Gratings(FBGs).Test data show that there are good linear relationships between the angles and the measured voltages.Less than 1% of angle measurement error is achieved in the measurement range.The FBG data are consistent with that of the resistance strain gauge,with linear correlation coefficient of 0.999.The FBG strain measurements are also reproducible.The relative deviation between twice strain measurements is only 1.22%.Results show that the aerodynamic parameters can be measured accurately.